poweron devicebay
The -poweron devicebay command sends a power-on request to Virtual Connect Manager for
a given bay.
Syntax
-poweron devicebay -enclosurename <enclosurename> -bayname <bayname>
Parameters
Table 30 Parameter descriptions for -poweron devicebay
OptionalRequiredDescriptionParameter
xSpecifies the name of the
enclosure that contains the
bay to be powered on.
-enclosurename
xSpecifies the name of the
bay to be powered on.
NOTE: For a multiblade
server, the bay name must
be the name of the primary
bay.
-bayname
Output
The result of the power-on operation. If nb is in effect for the command, nothing is returned, and
you can verify the results of the command by polling -show power-status for the enclosure
bay.
Examples
Power on a specific server in bay 2 of the enclosure enc0:
vcemcli -poweron devicebay enclosurename enc0 bayname 2
Power on a specific multi-blade server that occupies bays 1 to 4 of the enclosure enc0:
vcemcli -poweron devicebay enclosurename enc0 bayname 1
Minimum required role-based security
VCEM Group Limited Operator
Remarks
When nb is specified, this command does not indicate that the power has actually been turned
on. It is only an indication that the request has been successfully passed to Virtual Connect Manager.
The show power-status command must be polled to determine whether the bay has been
successfully powered on. An error is reported if the bay or enclosure name is invalid.
NOTE: When a timeout is specified, this command will block and poll the power status on an
interval defined by pollinginterval until the timeout is reached. A return of success means
the power is successfully turned on. The VCEMCLI will wait for a maximum of 3600 seconds (1
hour) by default when no timeout has been specified for the command.
Prerequisites
The bay must contain a server.