Figure 5 CPU utilization with selected percentiles of utilization
In this example, an allocation of three CPU cores is assumed, rather than the four cores initially
available in this exercise. Even this reduction may not provide the best fit, as the majority of the
work (90%) is completed with less than .5 of one core, and 99% of the work is completed with
one core.
For example, as shown in Figure 5 (page 22), CPU utilization has one peak at 1.7 CPU cores,
with many lower peaks. If you configure your system to always meet the demand of this single
1.7-CPU peak, and you do not adjust the CPU allocation, a significant fraction of the CPU allocation
in this example would go unused most of the time. Depending on your quality of service goals,
you may decide that a different configuration can better use the resources available. Further
experimentation in Capacity Advisor with resource allocations, consolidations, and utilization limits
will help you arrive at the best fit for these workloads.
With Capacity Advisor's visualization and reporting tools, you can make a considered estimate
of server resource utilization using different scenarios and easily refine allocations by tweaking
values in the scenarios. Such estimates can help you minimize overspending for capacity you use
rarely, and maximize utilization of your systems to ensure that your systems have the capacity
needed at the level you require.
Modeling considerations
Capacity Advisor methodology makes certain assumptions in its data analysis. These assumptions
include using an automatically determined CPU performance index, with normalization based on
benchmark data or benchmark data in combination with CPU clock speed in special cases.
Memory is not normalized. Scale factors can be set on the Capacity Advisor Edit Workload and
Move Workload screens. SeeAdjusting for platform changes” (page 179) for more information.
On the Edit Scenario screen, you can select either the System or Workload tab to manipulate the
planning scenario and specify which metric representation to view: average, 90th percentile, peak
or max 15-min (maximum 15-minute sustained). The Meter Style can be absolute numbers or in
percentages. By changing the metrics to view, you can explore multiple options for system and
workload deployment. See “ Controlling the data display” (page 67) for more information.
Capacity Advisor commands
In addition to tasks that you can perform from the Capacity Advisor graphical user interface,
Capacity Advisor provides several commands that can be run from the command line on an HP-UX
or Microsoft Windows CMS. For specific information, see “Command reference” (page 189).
22 Features
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 232 233

Commentaires sur ces manuels

Pas de commentaire

Tripp Lite SU6000RT3UHVXL podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zasilacze bezprzerwowe (UPS) Tripp Lite SU6000RT3UHVXL.
Dostarczamy 1 pdf podręczników Tripp Lite SU6000RT3UHVXL do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Zasilacze bezprzerwowe (UPS) Tripp Lite

Modele Rodzaj dokumentu
SU3000RTXLCD3U Arkusz Danych   Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial, 6 strony
SU1000XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 6 strony
SU2200XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 7 strony
SU2200RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
SU1000RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 6 strony
SU10KRT3/1X Arkusz Danych   Tripp Lite SmartOnline 3-Phase In/1-Phase Out 200-240V 10kVA 7kW On-Line, Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 6U Rack/Tower, USB, DB9 Serial, 5 strony
SMART2200RMXL2UP Arkusz Danych   Tripp Lite 2200 VA UPS, 6 strony
SM5000RT3UTAA Arkusz Danych   Tripp Lite SM5000RT3UTAA uninterruptible power supply (UPS), 6 strony
SMART1050SLTAA Arkusz Danych   Tripp Lite SMART1050SLTAA uninterruptible power supply (UPS), 6 strony
SMX3000RT2UTAA Arkusz Danych   Tripp Lite SMX3000RT2UTAA uninterruptible power supply (UPS), 6 strony
SU1500RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1.5kVA 1.35kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
HT-RL15UPS Arkusz Danych   Tripp Lite HTRL15UPS, 5 strony
SU16KRTHW Arkusz Danych   Tripp Lite SmartOnline 200-240V, 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU5000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 208/120V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, USB, DB9 Serial, 6 strony
SU12000RT4UHW Arkusz Danych   Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire, 6 strony
SU20KX Arkusz Danych   Tripp Lite SmartOnline 20kVA 16kW Modular 3-Phase UPS System, On-line Double-Conversion UPS, SNMP, Webcard, DB9 Serial, 5 strony
SU6000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 240/208/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Low-Voltage Transformer, Extended Run, SNMP, Webcard, 6U Rack/Tower, Bypass Switch, 7 strony
SU6000RT4UHVHW Arkusz Danych   Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU3000RTXR3UHW Arkusz Danych   Tripp Lite SmartOnline 110-120V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU40K Arkusz Danych   Tripp Lite SU40K uninterruptible power supply (UPS), 6 strony