Insight Control power management
HP iLO
Prerequisites
You will need “Matrix OE All Tools” permissions on the managed systems where you want to
calibrate power. (See Accessing Capacity Advisor” (page 37).)
Procedure 32 Open the Visualization tab
1. Select (ToolsHP Matrix OE visualization)
The Visualization tab opens.
2. View the list of systems in the display.
Calibrating a single system
There are multiple paths to edit the power settings for a single system:
On the Visualization tab, select the check box to the left of the desired physical system, and
select ConfigureCalibrate Power (All Selected Systems) on the visualization menu bar.
From the profile viewer for a specific system, click the Calibrate Power link.
TIP: Click the power meter on a physical system shown on the Visualization tab to view its
power information and to access the power profile viewer for that system.
Procedure 33 Selecting a calibration option for a single system
1. Review the current configuration shown in the summary area.
2. Click the radio button to the left of the desired calibration option.
3. Supply values for idle and maximum power usage when manual calibration is selected. (See
“Power calibration calculations” (page 185) for assistance in determining valid values for
particular systems.)
Procedure 34 Calibrating Insight Control power management
Click the “Calibrate” link.
Results are posted in the Last Attempted Auto-Calibration table.
If an error is indicated, read the “Troubleshooting” and “Notes” column for help on fixing the
error.
Procedure 35 Clearing current power management calibration values
Click the “Clear Calibration Data” link.
Calibration values are deleted. Results are posted in the Last Attempted Auto-Calibration table.
If an error is indicated, read the “Troubleshooting” and “Notes” column for help on fixing the
error.
Procedure 36 Updating HP iLO data and calibration
Click the “Collect iLO Data” link.
The latest power usage data for this system is obtained and used to update the calibration for
this system. Results are posted in the Last Attempted Auto-Calibration table.
If an error is indicated, read the “Troubleshooting” and “Notes” column for help on fixing the
error.
Procedure 37 Configuring power management
1. Examine the Power Management Plug-in Configuration table.
Working with power 85