The first threshold alarm email notification is generated when the performance value reaches
the minor threshold level (18).
The second threshold alarm email notification is generated only when the performance value
reaches the major threshold level (20).
When the performance value drops below the minor threshold level, another email notification
is generated. In the chart above, the row Time 2 shows a performance value of 15, which is
below the minor threshold level (18). You receive a threshold good information alarm email
notification.
Threshold monitoring 41