Display Messages
C-34 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
302 RECOVERY
ROM AUTOFLASH
FAILED
Error Indicates that the array
controller failed to copy
the current active
firmware image into the
backup recovery ROM.
Recovery ROM support
is disabled.
1. Remove the failing
array controller.
2. Wait 10 seconds.
3. Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
The controller reattempts
the ROM autoflash process
again.
If this action does not solve
the problem, contact HP
support.
303 ROM CLONING
STARTED
Informational Indicates that the two
array controllers in a
MSA500 system do not
have the same version of
firmware.
Controller firmware auto
cloning begins.
Refer to Chapter 4,
“Configuration and Utilities.”
304 ROM CLONING
DONE
Informational Indicates that the two
array controllers in a
MSA500 system
completed the firmware
cloning process.
continued