Hp StorageWorks 500 Modular Smart Array Manuel d'utilisateur Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 157
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
Hardware Options Installation
HP StorageWorks Modular Smart Array 500 System User Guide 3-11
Cache Upgrade Option
The controller ships with a 128-MB battery-backed cache module. A 256-MB
battery-backed cache module is available as an option. Before installing a cache
upgrade, observe the following guidelines:
Always power down the system before performing a cache upgrade.
If a controller has more than one cache DIMM, be sure that both DIMMs have
the same memory capacity.
Always upgrade the cache in both controllers in a system with redundant
controllers.
In a system with a redundant controller, be sure that both controllers have the
same number of DIMMs and that all DIMMs have the same memory capacity.
To upgrade the cache:
1. Power down the system. Refer to “System Power Down” in this chapter.
2. Remove the controller.
1
2
3
Vue de la page 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 156 157

Commentaires sur ces manuels

Pas de commentaire