Troubleshooting9–60
(For information on configuring email alerts, see Section 6.2.)
In the event of disk errors occurring, take action as described in the following sections:
Disks showing the removed/failed state (Section 9.34.1)
Disks showing the predict fail state (Section 9.34.2)
Disks showing the logging errors state (Section 9.34.3)
9.34.1 Disks showing the removed/failed state
The following is an example of an alert generated when a disk shows the removed/failed state:
array 4: disk Y69BMY3E has been removed or failed (was online)
In such cases, you must replace the failed disk as soon as possible. See Section 8.1.10 for information on
replacing a disk in an SFS20 array.
9.34.2 Disks showing the predict fail state
The following is an example of an alert generated when a disk shows the predict fail state:
array 1: disk bay 12 disk P6C8CX7 SMART predicts failure (was online)
In such cases, you must replace the disk as soon as possible, because predict fail errors indicate that
a disk is on the verge of failure. See Section 8.1.10 for information on replacing a disk in an SFS20 array.
9.34.3 Disks showing the logging errors state
The following is an example of an alert generated when a disk shows the logging errors state:
array 3: disk bay 7: disk Y69BLLYE is logging errors (was online)
In such cases, it is normally not necessary to replace the disk (a disk should not be replaced unless it is
generating a large number of errors). You should, however, investigate the matter further, by entering the
hpls_cciss_info
command on a server attached to the array, using the following syntax:
hpls_cciss_info -E -D controller,port,0,drive_number
For example:
# hpls_cciss_info -E -D 1,1,0,134
Disk 1,1,0,134: logged 32 start 12
[4] type 1 scsi_op 40 sense 0x3 qual 0 sense_code 0x11 (6146 mins ago)
Medium Error: Unrecovered read error
[5] type 2 scsi_op 40 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
[6] type 2 scsi_op 40 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
[7] type 2 scsi_op 42 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
[8] type 1 scsi_op 40 sense 0x3 qual 0 sense_code 0x11 (6146 mins ago)
Medium Error: Unrecovered read error
[9] type 2 scsi_op 40 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
[10] type 2 scsi_op 40 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
[11] type 2 scsi_op 42 sense 0x0 qual 0 sense_code 0x0 (6146 mins ago)
When you are examining the output from the hpls_cciss_info command, note the following points:
The sense 0x0 errors are transient, and can be ignored.
Although the Unrecovered read error (URE) messages are nontrivial, they are to be expected
on SATA drives; if the RAID functionality is operating normally on the array, the affected data is
reconstructed from the RAID parity stripe and rewritten.
Continue to monitor disks that are logging URE errors; if a particular disk (or disks) in an array is
frequently logging a lot (several hundred) of URE errors, the performance of the array may be
adversely affected.