Hp StorageWorks XP10000 Disk Array Manuel d'utilisateur Page 101

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 100
Command Line Interface Commands 101
Table 4-78 AddReplication Command Parameters
Parameter Name Status Description
groupname Optional Specify the group name used in the RAID Manager. The maximum
number of characters you can use to specify a group name is 31.
The group name cannot begin with a number sign (#) or a hyphen
(-).
NOTE: If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolhostid Required (Method 2 or 3) If you are using method 2 or 3, specify the ID of the host that
recognizes the primary volume (P-VOL).
NOTE: If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolinstancenum Required (Method 2) Specify the number of the Continuous Access XP instance that
manages P-VOL.
NOTE: If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolportnum Required (Method 3) If you are using method 3, specify the port number of the
Continuous Access XP instance that manages P-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer from
1 to 65535.
NOTE: If the replicationgroupid or pvolinstancenum
parameter is specified, this parameter is ignored.
svolhostid Required (Method 2 or 3) If you are using method 2 or 3, specify the ID of the host that
recognizes the secondary volume (S-VOL).
NOTE: If the replicationgroupid parameter is specified, this
parameter is ignored.
svolinstancenum Required (Method 2) Specify the number of the Continuous Access XP instance that
manages S-VOL.
NOTE: If the replicationgroupid parameter is specified, this
parameter is ignored.
svolportnum Required (Method 3) If you are using method 3, specify the port number of the
Continuous Access XP instance that manages S-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer from
1 to 65535
NOTE: If the replicationgroupid or svolinstancenum
parameter is specified, this parameter is ignored.
pvolarraytype Required Specify the model of the storage subsystem that contains P-VOL.
pvolserialnum Required Specify the serial number of the storage subsystem that contains
P-VOL.
pvoldevnum Required Specify the device number of P-VOL.
pvolportid Optional Specify the port ID in the Continuous Access XP configuration file
that manages P-VOL paths.
svolarraytype Required Specify the model of the storage subsystem that contains S-VOL.
svolserialnum Required Specify the serial number of the storage subsystem that contains S-
VOL.
svoldevnum Required Specify the device number of S-VOL.
svolportid Optional Specify the port ID in the Continuous Access XP configuration file
that manages S-VOL paths.
Vue de la page 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 117 118

Commentaires sur ces manuels