Command Line Interface Commands 20
Table 4-1 Extracting Parameter Values
To Find This Parameter Value: Do This:
lun Execute the GetStorageArray (subtarget=HostStorageDomain,
hsdsubinfo=freelun) command, specifying only the model and serialnum
parameters, HostStorageDomain for the subtarget parameter, and freelun for the
hsdsubinfo parameter. Use one of the lun values.
lungroupid Execute the GetStorageArray (subtarget=Port, portsubinfo=LUNGroup)
command, specifying only the model and serialnum parameters, and LUNGroup for the
portsubinfo parameter. Use the objectID value that appears under An instance
of LUNGroup.
lusedevnums Execute the GetStorageArray (subtarget=LDEV) command. Use the devNum value
of the LDEV for which path=false and onDemandDevice=false. Be sure that the
LDEVs have the same emulation, sizeInKB, and raidType attributes, specifying
them in the form of a comma-delimited list.
mastercontrollerid Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
masterserialnum Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
model Execute the GetStorageArray command. Use the displayArrayType value that
appears under An instance of StorageArray.
nickname Execute the GetStorageArray (subtarget=Port) command, specifying only the
model and serialnum parameters, Port for the subtarget parameter, and
HostStorageDomain for the portsubinfo parameter. The nickname value is
displayed under An instance of HostStorageDomain.
objectid Execute the GetStorageArray command, setting the subtarget corresponding to the
desired component, and then obtain the value from the execution result.
pdevid Execute the GetStorageArray (subtarget=PDEV) command, specifying only the
model and serialnum parameters, and PDEV for the subtarget parameter. The
objectID value that appears under An instance of PDEV consists of four parts, with
adjoining parts separated by a dot. Use the right-most value of objectID to specify the
pdevid parameter.
pdevnums Execute the GetStorageArray (subtarget=PDEV) command, specifying only the
model and serialnum parameters, and PDEV for the subtarget parameter. In the
execution result of this command, the objectID value that appears in a PDEV consists of
four parts, with adjoining parts separated by a dot. Enter the right-most value for the
pdevnums parameter. If there is more than one such value specified, separate them with
a comma.
port Execute the GetStorageArray (subtarget=Port) command, specifying only the
model and serialnum parameters, and the value for subtarget=Port. The portID
value appears under An instance of Port.
pvoldevnum Execute the GetHost command, and then obtain the value from the execution result.
pvolserialnum Execute the GetHost command. The pvolSerialNum is displayed as An instance
of ReplicationInfo.
remoteserialnum Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
remoteSSID Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
replicationgroupid Execute the GetHost command, and then obtain the value from the execution result.
serialnum Execute the GetStorageArray command, and then use the serialNumber value.
source Execute the GetAlerts command, and then obtain the value from the execution result.
svoldevnum Execute the GetHost command, and then obtain the value from the execution result.
svolsequencenum Execute the GetStorageArray command for the storage subsystem that contains the S-
VOL. Use the value of the sequenceNumber.