Command Line Interface Commands 59
4-3-15 ModifyPort
ModifyPort will change port and host storage domain attributes.
Users with access to this command:
Yes: System Administrator, Storage Administrator
No: Guest, Local System Administrator, Local Storage Administrator, Local Guest
Format for the StorageWorks XP12000/XP10000:
hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number
[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]
[channelspeed={0|1|2}] [lunsec={true|false}] [domain=domain-ID] [nickname=new-host-
storage-domain-name] [hostmode=new-host-mode-for-the-port] [hostModeOption=new-host-mode-
option-list]
Format for the StorageWorks XP1024/XP128:
hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number
[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]
[channelspeed={0|1|2}] [lunsec={true|false}] [domain=domain-ID] [nickname=new-host-
storage-domain-name] [hostmode=new-host-mode-for-the-port]
Format for the StorageWorks XP512/XP48:
hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number
[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]
[lunsec={true|false}] [domain=domain-ID] [hostmode=new-host-mode-for-the-port]
Table 4-34 ModifyPort Command Parameters
Parameter Name Status Description
serialnum Required Serial number of the port’s storage array.
model Required Model of the port’s storage array.
port Required Number of the port.
topology Optional New topology value for the port.
Possible values are as follows.
Fabric(on), FC-AL
Fabric(off), FC-AL
Fabric(on), Point-to-Point
Fabric(off), Point-to-Point
fibreaddr Optional New fibre channel address for the port (the hex string representation).
channelspeed Optional
(XP12000/XP10000 and
XP1024/XP128 only)
New transmission speed of a fiber channel for the port.
For StorageWorks XP12000/XP10000 and XP1024/XP128, you can
specify the following values:
0: automatic
1: 1 Gb/s
2: 2 Gb/s
lunsec Optional New setting for LUN security enabled (either “true” or “false”).
domain Optional DomainID of the Host Storage Domain (please refer to the notes).
nickname Optional
(XP12000/XP10000 and
XP1024/XP128)
Specify the nickname of the host storage domain. When you specify
this parameter, you must also specify the domain parameter.
The maximum number of characters that can be used for a nickname is
as follows:
StorageWorks XP12000/XP10000: 16 bytes
DKC microcode version 50-04-01 or later: 32 bytes
StorageWorks XP1024/128: 8 bytes