NOTE:
The change in the pane does
not
affect any port that satises one of the following conditions:
Theresultingnicknameisalreadyusedasthenicknameofahostbusadapter
connected to the port.
The resulting WWN exists in the port.
7. Click OK.Ifaconrmation message appears, click OK. Changes appear in blue in the tree.
NOTE:
If you select Apply this change to other ports, too,andclickOK, the Check WWNs dialog
box appears and lists the host bus adapters to be changed. To make the changes, click
OK.Ifnot,clickCancel.
Figure 52 Check WWNs dialog box
8. Click Apply.Aconrmation message appears.
9. Click OK. Settings are applied to the array.
Changing a host bus adapter's iSCSI name and nickname
In iSCSI environments, host bus adapters can be identied by iSCSI names or nicknames.
1. Start LUN Manager. The LUN Manager pane (Figure 15) appears.
2. In the tree, double-click the iSCSI folder. A list of iSCSI ports appears.
3. In the t
ree, right-click a host bus adapter (
), and select Change iSCSI name & Nickname.The
Change iSCSI name & Nickname pane appears.