Hp XP Command View Advanced Edition Software Manuel d'utilisateur Page 110

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 318
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 109
Command line interface commands
110
Table 4-38 GetStorageArray (subtarget=HostStorageDomain) command parameters
Parameter Name Status Description
domain
Optional Domain ID of the host storage domain
If you omit this parameter, all the host storage domains become the
target. If you specify this parameter, you must also specify the model and
serialnum parameters. This parameter can be specified in decimal and
hexadecimal. If you specify a hexadecimal number, add the 0x prefix.
NOTE: The execution results are output in decimal.
NOTE: If you specify this parameter, you must also specify the port or
portname parameter. If neither is specified, this parameter will be
ignored.
NOTE: Do not specify domain and domainnickname at the same time,
as this might cause an error to occur.
domainnickname
Optional
(for
XP24000/
XP20000,
XP12000/
XP10000/
SVS200,
and
XP1024/
XP128)
Nickname of the host storage domain
If you omit this parameter, all the host storage domains become the
target.
NOTE: If you this parameter, you must specify the port or portname
parameter. If neither is specified, this parameter will be ignored.
NOTE: Do not specify domain and domainnickname at the same time,
as this might cause an error to occur.
hsdsubinfo
Optional Specific information about the host storage domain
The values you can specify are WWN, Path, and FreeLUN. If you specify
multiple values at the same time, separate the values by commas.
port
Optional Number of the port containing the host storage domain
If port and portname are omitted, information about all ports is
displayed. If you specify this parameter, you must also specify the model
and serialnum parameters.
NOTE: If you specify this parameter, you must specify the domain or
domainnickname parameter. If neither is specified, this parameter will
be ignored.
NOTE: Do not specify port and portname at the same time, as this may
might cause an error to occur.
portname
Optional Port name of the host storage domain
If port and portname are omitted, information about all ports is
displayed. If you specify this parameter, you must also specify the model
and serialnum parameters.
NOTE: If you specify this parameter, you must specify the domain or
domainnickname parameter. If neither is specified, this parameter will
be ignored.
NOTE: Do not specify port and portname at the same time, as this may
might cause an error to occur.