Command line interface commands
96
Table 4-31 shows examples of specifying the parameter subtarget and the subinfo parameters.
Table 4-31 Examples of using the GetStorageArray command
Information to acquire Command specification
LDEV information
GetStorageArray subtarget=LDEV
Information about paths for logical units
GetStorageArray subtarget=LogicalUnit
lusubinfo=Path
Mapping information of external volumes for LDEVs
GetStorageArray subtarget=LDEV
ldevsubinfo=VolumeConnection
Information about logical units for array groups and
about LDEVs and paths for those logical units
GetStorageArray subtarget=ArrayGroup
arraygroupsubinfo=LogicalUnit
lusubinfo=LDEV,Path
Information about paths and WWNs for those paths
GetStorageArray subtarget=Path
pathsubinfo=WWN,HostInfo
Information about journal pools and logical units for
those journal groups
GetStorageArray subtarget=Pool
poolsubinfo=LogicalUnit
For details about parameters other than the parameter subtarget and the subinfo parameters,
see sections
4-4-17-2 to 4-4-17-18 .
4-4-17-2 GetStorageArray (subtarget not specified)
Executing GetStorageArray without the parameter subtarget specified obtains basic
information about storage subsystems already registered with the Device Manager server (see
Table 4-32).
To acquire information about a particular storage subsystem, specify the model in the model
parameter, and the serial number in the serialnum parameter.
A user to whom a user-defined resource group is assigned can obtain information about
storage subsystems that the user is permitted to access.
Table 4-32 GetStorageArray (subtarget not specified) command parameters
Parameter Name Status Description
model
Optional Model of the storage subsystem
If you omit this parameter, all storage subsystems become the target.
serialnum
Optional Serial number of the storage subsystem
If you omit this parameter, all storage subsystems become the target.
Command execution example: In this example, the CLI command obtains information about the
configuration of all the storage subsystems managed by the Device Manager server:
hdvmcli GetStorageArray
Command execution result:
RESPONSE:
An instance of StorageArray
objectID=*****
description= XP512 (10011) at 10.208.114.140
serialNumber=10011
arrayFamily=XP512/48
arrayType=XP512
Vue de la page 95