5-10 Performing Cross-Os File Exchange Operations
Hitachi USP V Cross-OS File Exchange User’s Guide
9. If you need to modify an existing line, go to the line to be modified using the
File-Load command, change the parameters as needed, and then use the
File-Save command to replace the line that was loaded.
10. If you need to insert a new line between existing lines, use a text editor later
to edit the file. You cannot add a new line between existing lines using the
FCU GUI for UNIX.
11. When you are finished adding lines to your new FCU parameter definition file,
make sure that you have selected the File-Save command for the last
parameter set you added or modified, and then select the File-Exit menu
command to close the file and exit FCU.
Creating Multiple Volume Definition Files (UNIX)
Multiple volume Dataset is supported for FXmto, when the version is 01-XX-
50/YY (XX=01 or 02) or later. Multiple volume Dataset is also supported for
FXotm when the version is 01-XX-60/YY (XX=02, 03 or 04) or later. The name
of the multiple volume definition file is “multidef.dat”. It must be placed
under the current directory where the FAL/FCU is to be executed. Specify the
other name in “FAL_MULTI_DEF_FILE” of the environment variable, if the
name of the multiple volume definition file want to be changed.
Note: Multiple volume Dataset is supported in the case of FileExchangeotm
when the version is 01-XX-60/YY(XX=02, 03 or 04) or higher.
Table 5-1 illustrates the VSN function.
Table 5-1 VSN Function
VSN:DSN[,VOLID1] VSN[,VOLID2] ----- VSN[,VOLIDn]
i) ii) iii) iv)
end
v)
e. i) This parameter is the information of the head volume:
VSN: a volume serial number with six digit of alphabet (A-Z, @, #,
and \) or numeral (0-9) characters.
DSN: dataset name.(Use maximum 44-digit of alphabet or numeral
character )
VOLID1: a VSN identification ( Omit this parameter if a VSN
identification is omitted in the volume definition file, and specify same
as the volume definition file, if a VSN identification is specified in the
volume definition file.)
f. ii) This parameter is the information of the second volume:
VSN: a volume serial number with six digit of alphabet (A-Z, @, #,
and \) or numeral (0-9) characters.