Troubleshooting 7-7
Hitachi USP V Cross-OS File Exchange User’s Guide
FCU Error Codes for UNIX
If FCU for UNIX reports an error, use the Help-Error command to view the
most recent error.
Table 7-3 lists and describes the FCU error codes for UNIX
and provides instructions for resolving each error condition. In
Table 7-3, the
error codes marked by an asterisk (*) may also be reported when I/O access
contention for the FX volume occurs between the z/OS and open-system
hosts. If the cause of the error cannot be identified as described in
Table 7-3,
check for any illegal I/O contention for the FX volume.
Note: Error codes with a negative value are FCU errors. Error codes with a
positive value are system errors. UNIX system error codes are defined in the
standard error file errno.h.
Note: The error codes with “(C)” in the “Error code” cell in
Table 7-3 are
generated only when using with FX Code Converter. For details, please see the
Hitachi Lightning 9900 V Series FX Code Converter User’s Guide (MK-
93RD152).
Table 7-3 FCU Error Codes for UNIX
Error
Code
Error Message and Description Recommended Action(s)
-100 No parameter file
The FCU parameter definition file
could not be found.
If you specified the parameter definition file using the
[param] option, make sure that the specified file exists and
the name is correct.
If you did not specify the [param] option when you started FCU, make sure
that the default parameter definition file exists (fcudata.param in the current
directory).
-101* Parameter file: Open error
An error occurred when opening
the parameter definition file.
Display the system error code using the Help-Error
command. Please refer to the OS user manual for
information on system errors.
-102* Parameter file: Read error
An error occurred when reading
the parameter definition file.
Display the system error code using the Help-Error
command. Please refer to the OS user manual for
information on system errors.
-103* Parameter file: No valid data
The parameters in the parameter
definition file are not valid.
Make sure that the FCU initiation parameters are entered
correctly in the parameter definition file.
-107 Parameter file: CODE_CONV error
The code conversion specified in
the parameter definition file is not
valid.
Make sure that the code conversion is specified as either EA
or No.
-108 Parameter file: PADDING error
The padding option specified in
the parameter definition file is not
valid.
Make sure that the padding is specified as either Yes or No.