Vue de la page 46
Small Form Factor D2700 disk enclosures maximum capacity
configuration
This example illustrates cabling for a single-domain configuration. In this configuration, note the
following:
P1 on the disk enclosure I/O module is treated as the SAS in port.
P2 on the disk enclosure I/O module is treated as the SAS out port.
In single-domain configurations, one cable path is created between the host, the primary disk en-
closure, and additional cascaded disk enclosures. (Shown)
In dual-domain configurations, two cable paths are created between the host, the primary disk
enclosure, and additional cascaded disk enclosures.
1. Host (server or controller
enclosure)
2. Primary disk enclosure
3. Additional cascaded disk
enclosure
D2600/D2700 Disk Enclosure User Guide 47