Hp ProLiant DL380p Gen8 Server Manuel d'utilisateur Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 134
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
Hardware options installation 67
2.
If you are not using an optional HP input cable, with the ground cable disconnected from the 48V power
source, crimp the ring tongues to the power and ground cables coming from the 48V source.
IMPORTANT: The power supply uses two power ring tongues and one ground ring tongue. They
are not interchangeable.
3. Remove the safety cover from the terminal block on the front of the power supply.
4. Remove the screws from the terminal block.
IMPORTANT: The minimum nominal thread diameter of a pillar or stud type terminal must be 3.5
mm (0.138 in); the diameter of a screw type terminal must be 4.0 mm (0.157 in).
Vue de la page 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 133 134

Commentaires sur ces manuels

Pas de commentaire