b.
Connect the 4-pin PATA power connector end of the extender cable to the second tape drive.
Item Description
1
SATA power connector to default optical drive
2
4-pin PATA power connector to the first tape drive
3
Extender cable 4-pin PATA power connector to the second
tape drive
17. Install the fan cage, and then connect the fan cables.
18. Install the full-length PCI cards that were removed.
19. Install the system air baffle (on page 30).
20. If removed, install the PCI air baffle (on page 29).
21. For tower models, do the following:
a. Install the access panel (on page 26).
b. Return the server to an upright position.
22. For rack models, do the following:
a. Install the access panel (on page 26).
b. Slide the server back into the rack.
23. Power up the server (on page 22).
24. Do one of the following:
o For tower models, install the bezel ("Install the tower bezel" on page 23).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Installing a storage controller
IMPORTANT: For additional installation and configuration information, refer to the
documentation that ships with the option.