Hardware options installation 87
12.
Remove the nonredundant power supply.
Installing the RPS Enablement Kit
1. Install the redundant power supply assembly:
a. Insert the redundant power supply assembly into the server chassis.
b. Secure the three internal screws and the thumbscrew on the redundant power supply back.
c. Secure the five external screws with T-10 and T-15 screwdrivers.
NOTE: When a Smart Array controller option is installed in the server, the capacitor holder must
be secured to the top of the power supply assembly.