Chapter 4 89
SCSI Connections
SCSI Bus Length Constraints
Ultra2 Wide Low-Voltage Differential SCSI Bus
Length
The maximum cable length for an Ultra2 Wide Low-Voltage Differential
SCSI bus is 12 meters. The HP VISUALIZE B1000/C3000 system uses 1
meter of this maximum cable length internally. This means that up to 11
meters of cable can be used for connecting external Ultra2 Wide
Low-Voltage Differential SCSI devices to this workstation.
NOTE When calculating the total Ultra2 Wide Low-Voltage Differential SCSI
cable/bus/trace length used externally, remember to account for cables
connecting external devices together as well as the bus length internal to
those devices.