Power Over Ethernet (PoE/PoE+) Operation
Displaying the Switch’s Global PoE Power Status
ProCurve(config)# show power-over-ethernet
Status and Counters - System Power Status
Pre-standard Detect : On
System Power Status : No redundancy
PoE Power Status : No redundancy
Chassis power-over-ethernet:
Total Available Power : 600 W
Total Failover Power : 300 W
Total Redundancy Power : 0 W
Total used Power : 9 W +/- 6W
Total Remaining Power : 591 W
Internal Power
1 300W/POE /Connected.
2 300W/POE /Connected.
3 Not Connected.
4 Not Connected.
External Power
EPS1 /Not Connected.
EPS2 /Not Connected.
Figure 11-3. Example of show power-over-ethernet Command Output