2. As needed, expand the drop-down boxes in the task area to change the settings from the suggested
defaults.
NOTE:
The SMU suggests defaults for the logical drive, creating one large logical drive from all
unused space on the array, with the highest fault tolerance and performance possible
for the hard drives included in that array.
•OnlyFault Tolerance levels possible for the array are displayed. For example, RAID 5
is not listed if the array has only two physical hard drives.
•ThedefaultStripe Size gives optimum performance in a mixed read/write environment.
For read-prominent environments, use a larger stripe size.
For write-prominent environments, use a smaller stripe size for RAID 5 or
RAID_ADG,andalargerstripesizeforRAID0orRAID1+0.
To build multiple logical drives on the same array, reduce the Size setting from the
default to a smaller amount. Additional logical drives can then be built from the
remaining unused space.
•DisablingtheArray Accelerator for a logical drive reserves use of the accelerator
cacheforotherlogicaldrivesinthearray.Thisfeatureisusefulifyouwanttheother
logicaldrivestohavethemaximumpossibleperformance.
3. When the display refreshes, verify that the congured logical drives are shown in the component list.
4. Repeat Step 1 through Step 3 to create additional logical drives for this array, or to create logical
drives for other arrays.
Congurationstatus-afterconguring hard drives
Figure 10 illustrates the current conguration.
The following items are congured:
Management port MA0 and MB0
DataportsSA0,SA1,SB0,andSB1
Physical hard drives, into:
Array A—Four (4) 160 GB hard drives, with no assigned spare
Logical drive 1—RAID 1+0
ArrayBThree(3)250GBharddrives,withanassignedspare
Logical drive 2RAID 5
Array C—Three (3) 250 GB hard drives, with an assigned spare
Logical drive 3RAID 5
42