7. From within the SMU, select Update > Controller > Flash Firmware.
8. Under the Flash Firmware banner, click Browse and navigate to the location of the previously-obtained
rmware le, and then click OK.
9. Wait for a completion message to display.
For example, the following messages are displayed on the MSA controller LCD panel:
M SA 1510 i u p d a t e s :
307 FIRMWARE FLASH DONE
MSA20 updates:
313 FIRMWARE FLASH DONE ON BOX <n>
(Each attached storage enclosure is updated one at a time, in sequential box number
order.)
NOTE:
Do not interfere with or cancel the download process. Interrupting the download process
might corrupt the rmware.
10. Restart the MSA and its attached storage enclosures storage system by doing the following (newly
downloaded rmware cannot be accessed until the MSA is restarted):
a. Press and hold down the MSA Power on/Standby button for approximately ve seconds to
place the MSA in Standby mode.
b. Power off all storage enclosures attached to the MSA.
c. Wait approximately two minutes to ensure that the hard disk drives in the enclosures stop
rotating.
d. Restart all storage enclosures attached to the MSA.
e. Wait approximately four minutes to allow the enclosures to complete their startup routines.
f. Press and release the MSA Power on/Standby button to restart the MSA.
g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA
controller LCD panel.
82
Update