Vue de la page 50
Figure 13 Sample conguration—after adding initiators
IMPORTANT:
Perform the following tasks to complete the conguration:
Enter secu
rity settings (optional, but recommended). (For more information, see
Security tasks on page 51.)
Enter conguration settings in the iSCSI initiator conguration software utility (on the server),
includin
g:
Adding target portals for the initiator to access.
•Conguring the target portals. (Be sure to select the option to automatically restore the connection
each tim
e the system restarts.)
Logging on to establish an active session.
Security tasks
Security can include one or all of the following:
Setting up Access Control Lists
Setting up CHAP authentication
Setting the SSL certicate
Setting up Access Control Lists
Access control lists (ACLs) provide security at the LUN level. In an ACL, you indicate the initiator(s) that
can access specic mapped logical drive units of a target.
NOTE:
Repeat all steps in this section for each target for which you want to establish an ACL.
1. From the server, open the iSCSI initiator software and close any active connections to the target. This
ensures that there is no I/O activity on the target.