If it has been more than six months since you restarted your MSA storage system, HP recommends
that you power-cycle the MSA (power off, and then power on) before updating the rmware to
ensure that you are working with a fresh system.
For newly installed MSA, do not perform a rmware update until controller batteries are fully
charged.
For existing MSA, do not perform a rmware update until you have conrmed that the “host
mode” or “prole” for each connection is correctly set. The host mode identies the operating
system of each connection to the storage. Do not use the default” setting. If the host mode is
not properly set, hosts may lose access to the storage or experience other difculties after the
update. Depending on your operating system environment or user preference, the host mode is
set through the “connection” commands of the CLI or through the “ACL settings of the SMU. For
more information, see the CLI or SMU user documents.
In dual controller MSA1510i congurations, you MUST log off all redundant paths to the MSA
array prior to beginning a rmware update. The update will not succeed if redundant paths are
detected by the MPIO/DSM and may require multiple reboots to recover back to the original
rmware version. There could also be potential loss of connection of the Internet Explorer to the
management port if there are redundant paths during the ash update cycle.
In dual controller MSA1510i congurations, only one of the two MSA controllers is updated
directly. The second MSA controller is updated (cloned) when the MSA is power-cycled near
the end of the updating procedure.
Depending on the storage enclosure model attached to the MSA array (SATA or SCSI), you may
be able to update enclosure rmware or hard drive rmware through the MSA utility.
After the update is complete, be sure to check the status of the MSA for unexpected issues.
After power-cycling the MSA array, verify the status of the connections, dened prole types,
redundancy settings, and storage conguration.
After the update is complete, power cycle the MSA and all of its attached hard drive storage
enclosures to activate the new rmware.
IMPORTANT:
If you encounter any problems during the rmware update process, stop and contact HP technical
support. See HP technical support” on page 11 for support contact information.
Updating MSA rmware
1. Determine which version rmware is currently installed on the MSA by using one of the following
methods:
With the array controller powered on, press the arrow buttons on the front of the controller until
the following message is displayed:
00 Array Controller Firmware ver <version>.
•FromtheSMU,selectView MSA1510i Controller. Then, view the Device Information in the right
pane of the screen for the Firmware Version.
80
Update