Changing Option
s for Logical Paths and Storage Systems
The DKC Option window (see Figure 51 on page 116) allows you to set the logical path options and
storage system options. These options will apply to the local storage system and the corresponding
remote storage
system.
To change logic
al path options and storage system options, follow the procedure below. Not only the
primary stora
ge system administrator but also the secondary storage system administrator can perform
this operation:
1. Ensure that the XP Remote Web Console main window is in Modify mode.
For detailed i
nformation about how to do this, please refer to XP Remote Web Console User’s Guide.
2. Ensure that the DKC Operation window is displayed.
3. In Display, select DKC.
4. Select LDKC f
rom the tree.
Thelistdisplaysalist of remote storagesystems.
5. From thelist, select andright-click thedesired remote storagesystem,
6. From the pop
-up menu, select DKC Operation and Change DKC Option.
The DKC Option window appears (Figure 51 on page 116).
7. On the DKC Option window, change the options as desired. For detailed information about the
options, refer to explanations below Figure 51 on page 116.
8. Select Set to close the DKC Option window.
9. See the Pre
view list to check the settings that you have made.
If you want to modify a setting, select and right-click the setting from the Preview list and then
select Modify. A window appears and allows you to modify the setting.
If you want to cancel a setting, select and right-click the setting in the Preview list and then
select Ca
ncel.
10. Select Apply to apply the settings that you have made. If an error occurs, the rightmost column of
the Preview list displays the error code. To view detailed information about the error, right-click
the error code and then select Error Detail. Anerror message appearsand givesyou detailed
information about the error.
Figure 51 DKC Option Window
The DKC Option window displays the following:
The Minimum Paths option species the minimum number of paths required for each remote
storage system connected to the local storage system (default = 1).
NOTE:
You cannot change the Minimum Paths for the current version.
The I/O missing interrupt handler (RIO MIH) Time setting species the RIO MIH timer value,
which is the wait time until data transfer from the local storage system to the remote storage
11 6
Conguring Disk Storage Systems and Logical Paths