CAUTION:
To avoid damage to the connectors, always install the dust covers or d ust caps whenever a transceiver
or a ber cable is disconnected. Remove the dust covers or dust caps from transceivers or ber cable
connectors only when they are connected. Do no t discard the dust covers.
To minimize the risk of contamination or damage, do the following:
Dust covers—Remove and set aside the dust covers and dust caps when installing an I/O module,
a transceiver or a cable. Install the d ust covers when disconnecting a transceiver or cable.
When to cleanIf a connector may be contaminated, or if a connector has not been protected by
a dust cover for an extended period of time, clean it.
How to clean:
1. Wipe the connector with a lint–free tissue soaked with 100% isopropyl alcohol.
2. Wipe the c onnector with a dry, lint–free tissue.
3. Dry the connector with moisture-free compressed air.
One of the many sources for cleaning equipment specically designed for ber optic connectors is:
AlcoaFujikuraLtd.
1-888-385-4587 (North America)
011 -1-770-956-7200 (International)