Specifications 79
HP 150 W Integrated Power Supply specifications
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 63 Hz
Rated input current
3.5 A at 100 V AC
Rated input power
< 192W at 100 V AC
< 185 W at 200 V AC
Efficiency (minimum)
79%
Power supply output
Rated steady-state power
150 W at 100 V AC
150 W at 200 V AC
Maximum peak power
150 W at 100 V AC
150 W at 200 V AC
Rated output power
150 W
HP 200 W Integrated Power Supply specifications
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 63 Hz
Rated input current
3.5 A at 100 V AC
Rated input power
< 243 W at 100 V AC
< 237 W at 200 V AC
Efficiency
81.5%
Power supply output
Rated steady-state power
200 W at 100 V AC
200 W at 200 V AC
Maximum peak power
200 W at 100 V AC
200 W at 200 V AC
Rated output power
200 W