Logical
The state of the component as known to the operating system on the server.
Values
Device State
A code that identifies the generation of the component provided by its
supplier.
Vendor Hardware Revision
Device Connection
The location of the configured FCSA connected to the FC-AL I/O Module.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Configured Controller Location
The number that identifies the FCSA FSAC connected to the FC-AL I/O
Module.
Example: FCSA FSAC (111.2.1.1)
Fibre Channel Controller
Actions
Blink LED Off
Turns off the blinking of the FC-AL I/O Module’s (amber) fault LED.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF
Blink LED On
Causes the FC-AL I/O Module’s (amber) fault LED to blink on and off.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED ON
Replace
Displays the procedure for replacing the FC-AL I/O module.
FCDM
Fibre Channel disk modules (FCDMs), formerly known as Disk Drive Enclosures, are located in the
OSM Service Connection tree pane hierarchy under FCDM Collection objects. (See FCDM Collection
for more information on where they appear in the tree hierarchy.) Each FCDM contains:
Up to 14 Fibre Channel disk drives
Two FC-AL I/O Modules
Two Power Supplies
Two Blowers
One EMU
Location in OSM Tree: System > Group > FCDM Collection > FCDM
Example: FCDM (111.211.1)
Attributes
FCDM
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
144 System Resources