Test Basic Online
Runs an online test to determine if the CLIP is functional, and checks that both the access paths are
available.
Test Full Path Access
Tests two-way access to the communications line interface processor (CLIP) using both the primary
and alternate addresses.
Test Primary Path Access
Tests two-way access to the communications line interface processor (CLIP) using the primary
address
Test Verify
Runs the power-on self-test for the CLIP. The FAULT LED on the CLIP flashes during the test. If the
test passes, the FAULT LED goes off. If the test fails, the FAULT LED remains on continuously.
SWAN Collection
When one or more SWAN or SWAN 2 concentrator CRUs are connected to a system, a SWAN
Collection object appears in both the tree pane and the overview pane of the OSM Service
Connection. In both panes, this object displays an alarm or yellow icon if alarms or degraded
conditions exist on any of the individual SWAN CRUs contained within. You can expand the
SWAN Collection icon in the tree pane (but not in the overview pane) to select and monitor
individual SWAN CRUs and their subcomponents.
Location in OSM Tree: Under System
Example: SWAN Collection
Attributes
None.
Actions
None.
SWAN FAN
Each SWAN 2 CRU has two customer-replaceable fan subcomponents.
Location in OSM Tree: System > SWAN Collection > SWAN > Fan
Example: Fan $ZZWAN.#SWAN2.FAN1
Attributes
Fan $ZZWAN
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Logical
The state of the component as known to the operating system on the server.
Values
Device State