Attributes
Power Supply
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Physical
Indicates whether or not the power supply’s (amber) fault LED is blinking.
Value: Blinking or Off
LED State
The vendor hardware type.Type
Logical
Whether the power source is On or Off.AC Power State
The state of the component as known to the operating system on the server.
Values
Device State
A code that identifies the generation of the component provided by its
supplier.
Vendor Hardware Revision
Actions
Blink LED Off
Turns off the blinking of the power supply’s (amber) fault LED.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF
Blink LED On
Causes the power supply’s (amber) fault LED to start blinking.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED ON
Replace
Displays the procedure for replacing the power supply.
Power Supply (IOAM)
Supplies power to the IOAM. There are two IOAM power supply units in each IOAM.
For information on how to replace an individual Power Supply, see the Support and Service >
Service Procedures collection in NTL.
NOTE: If a ServerNet switch board is not present, the IOAM power supplies will not appear in
OSM.
Location in OSM Tree: System > Group > IOAM Enclosure > IOAM > Power Supply
Example: Power Supply (13.2.15)
192 System Resources