Configure Power Source as UPS
Sets the Power Source attribute value for this power supply unit to UPS. You must be logged on as
super.super to perform this action. Upon initiating the action, you are prompted to enter the IPv4
address of the UPS.
For Integrity NonStop NS16000 series servers, you must use this action to configure at least one
of your processor switch power supplies (to specify UPS as the backup power source) in order for
OSM to provide an orderly system shutdown in the event that a power failure exceeds the
powerfail-delay time interval specified for your UPS. For more information on preparing for AC
power-fail scenarios, see the NonStop NS16000 Series Planning Guide. For more information on
using the POWERFAIL_DELAY_TIME command to specify the Power-Failure-to-Shutdown time interval,
see the SCF Reference Manual for the Kernel Subsystem.
Delete the Power Source Configuration
Sets the Configuration > Power Supply attribute value to Not Configured. You must be logged on
as super.super to perform this action.
Replace
Launches the guided procedure to replace a processor switch power supply.
Set LED State
Turns on or off the amber LED located on the PIC port. The current state is indicated by the LED
State attribute.
Power Supply (SAS Disk Enclosure)
A subcomponent of a SAS Disk Enclosure.
System > SAS Disk Enclosures > SAS Disk Enclosure > Power Supply
Attributes
None.
Actions
Replace
Launches a documented service procedure to replace a power supply in a SAS disk enclosure.
Power Supply and Fan (Telco SAS Disk Enclosure)
In the OSM Service Connection, a subcomponent displayed for a Telco SAS Disk Enclosure only.
In commercial SAS Disk Enclosures, SAS Power Supplies and SAS Fans are represented by separate
objects in OSM.
System > SAS Disk Enclosures > SAS Disk Enclosure > Power Supply and Fan
Attributes
None.
Actions
Replace
Launches a documented service procedure to replace a power supply or fan in a Telco SAS disk
enclosure.
Power Supply (SAS Disk Enclosure) 195
Commentaires sur ces manuels