Hp Integrity NonStop J-Series Manuel d'utilisateur Page 196

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 328
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 195
Power Supply (VIO)
Provides power to the VIO enclosure (represented in the OSM Service Connection as a VIO module).
There are two VIO power supplies in each VIO enclosure.
Attributes
VIO Power Supply
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Physical
Identifies the manufacturer of the component.
Displayed for VIO power supplies in S-series VIO modules only.
Manufacturer
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
Logical
The state of the component as known to the operating system on the server.
Values
Device State
Configuration
NOTE: These attributes are not displayed for a power supply unit in an S-series VIO Module.
Indicates the state of this power supply's backup power configuration as
known to OSM.
Values: Not Configured, AC, UPS, Unknown
You must use the Configure Power Source as UPS action to set this value to
UPS in order for OSM to provide an orderly system shutdown in the event
that a power failure exceeds the powerfail-delay time interval specified for
your rack-integrated UPS.
Power Source
The IPv4 address of the UPS configured to provide backup power in the event
of a power failure, if specified through the Configure Power Source as UPS
action.
UPS IPv4 Address
Actions
Configure Power Source as AC
Sets the Configuration > Power Supply attribute value for this power supply to AC. You must be
logged on as super.super to perform this action.
NOTE: This action is not valid for a power supply unit in an S-series VIO Module.
Configure Power Source as UPS
Sets the Power Source attribute value for this power supply to UPS. You must be logged on as
super.super to perform this action. Upon initiating the action, you are prompted to enter the IPv4
address of the UPS.
You must use this action to configure at least one of your VIO power supplies (to specify UPS as
the backup power source) in order for OSM to provide an orderly system shutdown in the event
196 System Resources
Vue de la page 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 327 328

Commentaires sur ces manuels

Pas de commentaire