Example
EM-78E7D1C12074> show server temp all
Device Bay #1 Temperature Information
Locale Status Temp Caution Critical
---------------------------------- ------ -------- ------- --------
Ambient Zone OK 23C/ 73F 42C 46C
CPU 1 OK 40C/104F 82C 83C
CPU 2 OK N/A
Memory Zone OK 32C/ 89F 87C 92C
Memory Zone OK 30C/ 86F 85C 90C
Memory Zone OK 37C/ 98F 85C 90C
System Zone OK 37C/ 98F 85C 90C
System Zone OK 39C/102F 78C 83C
System Zone OK 52C/125F 110C 115C
Drive Backplane OK 21C/ 69F 60C 65C
Device Bay #2 Temperature Information
Locale Status Temp Caution Critical
--------------------------------- ------ -------- ------- --------
Ambient Zone OK 23C/ 73F 42C 46C
CPU 1 OK 40C/104F 82C 83C
CPU 2 OK N/A
Memory Zone OK 31C/ 87F 87C 92C
Memory Zone OK 29C/ 84F 85C 90C
Memory Zone OK 36C/ 96F 85C 90C
System Zone OK 36C/ 96F 85C 90C
System Zone OK 38C/100F 78C 83C
System Zone OK 49C/120F 110C 15C
Drive Backplane OK 15C/ 59F 60C 65C
Internet control
The EM bridges two networks: an external network and an internal network. The iLO of both servers
is connected to the internal network, and EM uses this network to interact with iLO using IPMI
messages to control the servers. EM also bridges the two iLO management processors to the external
management LAN for other software and to enable users to interact with iLO directly. Only the
two servers and the two SAS IO modules are connected. CSP IO modules have no web-based user
interface, so EBIPA is used exclusively for the 2 iLO management processors in the blades.
The following commands define the EM 1.0 CLI functions for Internet control in CSP.
ADD EBIPA
Syntax
ADD EBIPA { SERVER } DNS <ip address>
Description
Adds an EBIPA DNS server IP address to the list of DNS servers for server bays.
Restrictions
A maximum of 3 DNS servers can be added for EBIPA.
<ip address> must be in the form ###.###.###, where each ### ranges from 0 to 255.
REMOVE EPIBA
Syntax
REMOVE EBIPA { SERVER } DNS <ip address>
Description
Removes an EBIPA DNS server IP address from the list of DNS servers for server bays.
CLI reference 169
Vue de la page 168
1 2 ... 164 165 166 167 168 169 170 171 172 173 174 ... 206 207

Commentaires sur ces manuels

Pas de commentaire

Tripp Lite SU6000RT3UHVXL podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zasilacze bezprzerwowe (UPS) Tripp Lite SU6000RT3UHVXL.
Dostarczamy 1 pdf podręczników Tripp Lite SU6000RT3UHVXL do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Zasilacze bezprzerwowe (UPS) Tripp Lite

Modele Rodzaj dokumentu
SU3000RTXLCD3U Arkusz Danych   Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial, 6 strony
SU1000XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 6 strony
SU2200XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 7 strony
SU2200RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
SU1000RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 6 strony
SU10KRT3/1X Arkusz Danych   Tripp Lite SmartOnline 3-Phase In/1-Phase Out 200-240V 10kVA 7kW On-Line, Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 6U Rack/Tower, USB, DB9 Serial, 5 strony
SMART2200RMXL2UP Arkusz Danych   Tripp Lite 2200 VA UPS, 6 strony
SM5000RT3UTAA Arkusz Danych   Tripp Lite SM5000RT3UTAA uninterruptible power supply (UPS), 6 strony
SMART1050SLTAA Arkusz Danych   Tripp Lite SMART1050SLTAA uninterruptible power supply (UPS), 6 strony
SMX3000RT2UTAA Arkusz Danych   Tripp Lite SMX3000RT2UTAA uninterruptible power supply (UPS), 6 strony
SU1500RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1.5kVA 1.35kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
HT-RL15UPS Arkusz Danych   Tripp Lite HTRL15UPS, 5 strony
SU16KRTHW Arkusz Danych   Tripp Lite SmartOnline 200-240V, 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU5000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 208/120V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, USB, DB9 Serial, 6 strony
SU12000RT4UHW Arkusz Danych   Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire, 6 strony
SU20KX Arkusz Danych   Tripp Lite SmartOnline 20kVA 16kW Modular 3-Phase UPS System, On-line Double-Conversion UPS, SNMP, Webcard, DB9 Serial, 5 strony
SU6000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 240/208/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Low-Voltage Transformer, Extended Run, SNMP, Webcard, 6U Rack/Tower, Bypass Switch, 7 strony
SU6000RT4UHVHW Arkusz Danych   Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU3000RTXR3UHW Arkusz Danych   Tripp Lite SmartOnline 110-120V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU40K Arkusz Danych   Tripp Lite SU40K uninterruptible power supply (UPS), 6 strony