Status Conditions and Sense Code Information 321
Managing the Disk Array
on HP-UX
Component Status Conditions
Component status conditions are organized into the categories listed in Table 42. The
interpretation and action associated with a status depends on the component. See Table 51
on page 379 for more information on Disk System SC10 component status.
The component status condition terminology used by Array Manager 60 (AM60) may differ
from that used by STM. Both terms are identified in the table.
Table 42 Component Status Conditions
Status Description
AM60:
Good
STM:
Optimal
The component is operating normally.
AM60:
Non-critical
STM:
Fault - 3
A component or condition such as temperature or voltage
has exceeded warning limits.
Although immediate action is not required, the cause of
the non-critical status should be investigated and
corrected if necessary.
AM60:
Critical
STM:
Fault - 2
A component has failed or a condition such as
temperature or voltage has exceeded critical limits.
Immediate action is required.
AM60:
Not Installed
STM:
Not Present
The component is not installed.
AM60:
Unknown
STM:
Fault - 0
The status of the component cannot be determined.