Vue de la page 340
Status Conditions and Sense Code Information 341
Managing the Disk Array
on HP-UX
91 36 Command Lock Violation
The controller received a Write Buffer Download Microcode,
Send Diagnostic, or Mode Select command, but only one such
command is allowed at a time and there was another such com-
mand active.
91 3B Improper Volume Definition for Auto-Volume Transfer mode -
AVT is disabled.
Controller will operate in normal redundant controller mode
without performing Auto-Volume transfers.
91 50 Illegal Operation For Drive Group State
An operation was requested that cannot be executed due to the
current state of the Drive Group.
91 51 Illegal Reconfiguration Request - Legacy Constraint
Command could not be completed due to Legacy configuration
or definition constraints
91 53 Illegal Reconfiguration Request - System Resource Constraint
Command could not be completed due to resource limitations
of the controller
94 01 Invalid Request Due to Current Logical Unit Ownership
95 01 Extended Drive Insertion/Removal Signal
The controller has detected the drive insertion/removal signal
permanently active.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation