Vue de la page 95
96 Recommended Disk Array Configurations
Six Disk Enclosure Configurations
High Availability/High Performance
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Six disk enclosures with ten 73 GByte disks each (60 disks total)
Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
LUN Configuration
Ten RAID 0/1 LUNs, each comprising six disks (3+3)
Each disk in a LUN is in a separate enclosure
High Availability
Handles a single disk failure, single BCC failure, single channel failure, or a single
controller failure
Disk Capacity
Maximum capacity 4380 GBytes
Usable capacity 2190 GBytes