Hp Surestore Disk Array 12h and FC60 Manuel d'utilisateur Page 57

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 466
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 56
Disk Array High Availability Features 57
Product Description
RAID Level Comparisons
To help you decide which RAID level to select for a LUN, the following tables compare the
characteristics for the supported RAID levels. Where appropriate, the relative strengths
and weakness of each RAID level are noted.
Note
RAID 3 is supported on Windows NT and Windows 2000 only.
Table 1
RAID Level Comparison: Data Redundancy Characteristics
RAID Level Disk Striping Mirroring Parity
Handle multiple disk
failures?
RAID 0 Yes No No No. RAID 0 offers no data
redundancy or protection
against disk failure. RAID 0
should only be used for non-
critical data. The failure of a
single disk in a RAID 0 LUN
will result in the loss of all
data on the LUN.
RAID 1 No Yes No No
RAID 0/1 Yes Yes No Yes, providing both disks in
a mirrored pair do not fail.
RAID 3 Yes No Yes No
RAID 5 Yes No Yes No
Vue de la page 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 465 466

Commentaires sur ces manuels