Hp Surestore Disk Array 12h and FC60 Manuel d'utilisateur Page 86

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 466
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 85
86 Recommended Disk Array Configurations
Maximum Capacity
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Three disk enclosures with ten 73 GByte disks each (30 disks total)
Disk enclosures configured for split-bus mode (two SCSI channels per enclosure)
LUN Configuration
Ten RAID 5 LUNs, each comprising three disks (2 data + 1 parity).
Each disk in a LUN is in a separate enclosure.
High Availability
Handles a single disk failure, single controller, single channel, single BCC, or a single
disk enclosure failure
Expansion requires powering down the disk array, recabling the array to a full bus
configuration, rebinding the LUNs, and restoring all data
Disk Capacity
Maximum capacity 2190 GBytes
Usable capacity 1460 GBytes
Vue de la page 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 465 466

Commentaires sur ces manuels

Pas de commentaire