94 Recommended Disk Array Configurations
Maximum Capacity
Hardware
Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Five disk enclosures with ten 73 GByte disks each (50 disks total)
Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
LUN Configuration
Ten RAID 5 LUNs, each comprising five disks (4 data + 1 parity)
Each disk in a LUN is in a separate enclosure.
High Availability
Handles a single disk failure, single disk enclosure/BCC failure, single channel
failure, or a single controller failure
Expansion requires powering down the disk array, and adding an additional disk
enclosure and cabling
Disk Capacity
Maximum capacity 3650 GBytes
Usable capacity 2920 GBytes
Vue de la page 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 465 466