Hp Surestore Disk Array 12h and FC60 Manuel d'utilisateur Page 336

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 466
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 335
336 Status Conditions and Sense Code Information
40 NN Diagnostic Failure on Component NN (0x80 - 0xFF)
The controller has detected the failure of an internal controller
component. This failure may have been detected during opera-
tion as well as during an on-board diagnostic routine. The val-
ues of NN supported in this release of the software are listed
below.
80 - Processor RAM
81 - RAID Buffer
82 - NVSRAM
83 - RAID Parity Assist (RPA) chip or cache holdup battery
84 - Battery Backed NVSRAM or Clock Failure
91 - Diagnostic Self Test failed non-data transfer components
test
92 - Diagnostic SelfTest failed data transfer components test
93 - Diagnostic SelfTest failed drive Read/ Write Buffer data
turnaround test
94 - Diagnostic Self Test failed drive Inquiry access test
95 - Diagnostic Self Test failed drive Read/ Write data turn-
around test
96 - Diagnostic Self Test failed drive Self Test
43 00 Message Error
The controller attempted to send a message to the host, but the
host responded with a Reject message.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation
Vue de la page 335
1 2 ... 331 332 333 334 335 336 337 338 339 340 341 ... 465 466

Commentaires sur ces manuels

Pas de commentaire