Page 1 - (1.13 and 1.26 GHz)

HP Netserver LP 2000r User Guide (1.13 and 1.26 GHz) Online Version: 2.0 Last Updated: June 2001

Page 2 - Audience Assumptions

Chapter 1 Controls, Ports and Indicators 4 Rear Panel The ports and connectors at the rear are listed below and shown in Figure 1-3. • The power co

Page 3 - Contents

Chapter 10 Configuring the HP Netserver 94 Contents of the HP Netserver Navigator CD-ROM The Main Menu of the Navigator CD directs you to modules w

Page 4

Chapter 10 Configuring the HP Netserver 95 Status Report Identification You must compare the Document Number on your HP Netserver Navigator CD with

Page 5

Chapter 10 Configuring the HP Netserver 96 • HP TopTools Remote Control Card – This is an accessory PCI board that provides a connection for remote

Page 6

Chapter 10 Configuring the HP Netserver 97 Accessing the Setup Utility The (BIOS) Setup Utility menu offers the choices listed above, and the corres

Page 7 - Front Panel

Chapter 10 Configuring the HP Netserver 98 o Embedded LAN Controllers - Enable or disable the embedded LAN controllers and the available features. T

Page 8

Chapter 10 Configuring the HP Netserver 99 Once in the Setup Utility, the menu bar appears at the top of the screen with "User Preferences, Sec

Page 9 - LED ICON Description

Chapter 10 Configuring the HP Netserver 100 2. Use the right-arrow or left-arrow key to select Security from the menu bar. As soon as it is select

Page 10 - Rear Panel

Chapter 10 Configuring the HP Netserver 101 5. Enter the password (new or old) in the appropriate field and press Enter. The password is accepted

Page 11

Chapter 10 Configuring the HP Netserver 102 To access the Symbios SCSI Configuration Utility, refer to the following instructions. 1. Reboot the HP

Page 12 - Powering-Up the HP Netserver

103 11 HP Netserver Online Documentation CD-ROM Overview The HP Netserver Online Documentation CD-ROM contains the entire set of documentation for y

Page 13 - Sleep States (ACPI)

Chapter 1 Controls, Ports and Indicators 5 Power Mouse ParallelLAN A/MGMTLAN BPCI Slot (1)KeyboardSerial A/MGMTVideo ExternalSCSI Connector Figure 1-

Page 15 - Netserver

105 12 Troubleshooting Introduction If you are having problems installing your HP Netserver, there are a number of tools available for troubleshootin

Page 16 - Removing the Top Cover

Chapter 12 Troubleshooting 106 Common Installation Problems The following sections contain general procedures to help you locate installation problem

Page 17 - Replacing the Top Cover

Chapter 12 Troubleshooting 107 Netserver Will Not Power On Follow these steps if the power/activity light does not light green after you press the po

Page 18

Chapter 12 Troubleshooting 108 For example, reduce the Netserver to the monitor, one flexible disk drive, one CD-ROM drive, one SCSI hard disk drive,

Page 19 - Air Flow Guide

Chapter 12 Troubleshooting 109 10. Choose the Exit option and save the changes to save the configuration and exit the Setup Utility. Spring LatchBa

Page 20 - Removing the PCI Card Cage

Chapter 12 Troubleshooting 110 Resetting a Lost Password If you have forgotten the Power-on password, you can reset it using the configuration switch

Page 21 - Replacing the PCI Card Cage

Chapter 12 Troubleshooting 111 Hardware Problems This section describes what to do if you have problems with your monitor, mass storage devices, prin

Page 22

Chapter 12 Troubleshooting 112 Keyboard or Mouse Does Not Work 1. Verify the keyboard and mouse are connected to the correct connectors. Refer to th

Page 23

Chapter 12 Troubleshooting 113 Replacing a Battery If your HP Netserver repeatedly loses its configuration or the processor clock stops, you should r

Page 24

Chapter 1 Controls, Ports and Indicators 6 Applying Power to the HP Netserver Powering-Up the HP Netserver 1. Turn on power to the monitor connecte

Page 25 - Boot Priority

Chapter 12 Troubleshooting 114 Figure 12-3. Battery on System Board 7. Insert the new battery with the positive sign (+) facing up. Push the bat

Page 26 - Hardware Mirroring

115 13 Alternative Rack Mounting (4-Post) Introduction This chapter provides the instructions for mounting the HP Netserver in an older 4-post HP Sy

Page 27

Chapter 13 Alternative Rack Mounting (4–Post) 116 EDABCharacteristics ofHP System rack:A.B.C.D.E.3-Cornered columnsFan-Only Vent“HP systems” namePla

Page 28

Chapter 13 Alternative Rack Mounting (4–Post) 117 The HP Netserver LP 2000r rack mount kit requires two EIA units of space in the rack. Before mounti

Page 29

Chapter 13 Alternative Rack Mounting (4–Post) 118 The white papers, specifically HP Netserver High Density Rack Solutions Overview (LP 1000r and LP

Page 30

Chapter 13 Alternative Rack Mounting (4–Post) 119 Marking the Columns To make it easier to install the slides in the rack, you may want to mark the c

Page 31

Chapter 13 Alternative Rack Mounting (4–Post) 120 Installing the Slides in the Rack 1. Prepare both slides for installation: a. Remove the spring

Page 32

Chapter 13 Alternative Rack Mounting (4–Post) 121 2. Attach the brackets to the front columns, using the two screws provided in the hardware kit. Se

Page 33

Chapter 13 Alternative Rack Mounting (4–Post) 122 b. Tighten the nuts (saved from Step 1) onto the slide bolts to secure the slides to the columns.

Page 34 - Bottom Connector

Chapter 13 Alternative Rack Mounting (4–Post) 123 Mounting the HP Netserver on the Slides Use this procedure to insert the HP Netserver into the slid

Page 35

Chapter 1 Controls, Ports and Indicators 7 Connecting AC Power to Multiple-Server Configurations The HP Netserver temporarily draws a large "inr

Page 36

Chapter 13 Alternative Rack Mounting (4–Post) 124 Figure 13-6. Mounting the HP Netserver on the Slides

Page 37

Chapter 13 Alternative Rack Mounting (4–Post) 125 Figure 13-7. Pressing the Stop Release Attaching the Front Bezel 1. Position the bezel in fro

Page 38 - Installing Additional DIMMs

Chapter 13 Alternative Rack Mounting (4–Post) 126 PinPinBA Figure 13-8. Attaching the Bezel to the HP Netserver Cabling Rack Components After ins

Page 39

Chapter 13 Alternative Rack Mounting (4–Post) 127 Attaching the Cable Management Arm The Cable Management Arm (CMA) allows the cables and power cord

Page 41

129 A Specifications Introduction This appendix provides the power requirements, operating conditions (environmental requirements), physical requirem

Page 42 - Removing DIMMs

Appendix A Specifications 130 Table A-2. Environmental Requirements Parameter Conditions Temperature Operating 5° to 35° C (41° to 95° F) NOTE • S

Page 43

Appendix A Specifications 131 Table A-3. Weight and Dimensions Weight___________38 lbs. (17.3 kg.) fully loaded (6 SCSI HDDs, 2 processors, and 4 DIM

Page 44

Appendix A Specifications 132 Table A-5. Video Display Modes Resolution Max. Refresh Rate @ 256 Colors Max. Refresh Rate @ 65K Colors

Page 45

Appendix A Specifications 133 Wake-on-LAN (WOL)Not UsedWake-on-Ring (WOR)Not UsedIntegrated RABoardConnectors (2)(DaughterBoard)PCI BoardFanPower, R

Page 46 - IRQ Settings

Chapter 1 Controls, Ports and Indicators 8 The Netserver supports certain types of system activity, which is used as wake-up events from these sleep

Page 48 - Connector

135 Index A accessory board installing, 42 removing, 47 ACPI Advanced Configuration and Power Interface, 2, 7 Advanced Configuration and Power Interf

Page 49

Index 136 DIMMs installation guidelines, 32 installing, 31, 32 non-compatible, 31 open slot configuration, 32 removing, 36 retaining latches, 37 slots

Page 50

Index 137 HP Netserver Online Documentation CD-ROM, 103 automatic start, 103 I I2C connector supported, 41 IDE device Setup Utility, 97 IDE Setup Uti

Page 51

Index 138 keyboard, 4 LAN port, 4 mouse, 4 ports external, 87 keyboard, 87 mouse, 87 parallel, 4 rear panel, 4 serial ports, 87 USB ports, 87 video, 4

Page 52

Index 139 Exit menu, 98 flexible disk drive, 97 hardware security, 97 IDE devices, 97 IDE primary/secondary, 97 integrated I/O port, 97 LAN A Power O

Page 53 - Removing an Accessory Board

Index 140 Wake-on-LAN Magic Packet, 96 weight, 131 weight and dimensions, 131 Z Zero Insertion Force ZIF, 52 ZIF Zero Insertion Force, 52

Page 54

9 2 Opening and Closing the HP Netserver Introduction This chapter describes how to the remove the front bezel, top cover, and air flow guide from t

Page 55

Chapter 2 Opening and Closing the HP Netserver 10 Figure 2-1. Removing the Front Bezel Replacing the Front Bezel 1. Hook the bottom edge of the

Page 56 - Processor

Chapter 2 Opening and Closing the HP Netserver 11 4. Release the top cover by turning the knob at the front of the chassis in a clockwise direction.

Page 57

Chapter 2 Opening and Closing the HP Netserver 12 BA Figure 2-3. Replacing the Cover 3. Turn the knob to the Closed position (counter-clockwise). Se

Page 58

Chapter 2 Opening and Closing the HP Netserver 13 Removing the Rear Chassis Blower/Bracket and Air Flow Guide The blower generates the air that cools

Page 59 - Terminator

ii Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to

Page 60

Chapter 2 Opening and Closing the HP Netserver 14 Replacing the Rear Chassis Blower/Bracket and Air Flow Guide To replace the rear chassis blower/bra

Page 61 - Installing the Heatsink

Chapter 2 Opening and Closing the HP Netserver 15 Replacing the PCI Card Cage Follow these steps to replace the PCI card cage and reconnect the card

Page 63

17 3 Installing Mass Storage Devices Introduction The HP Netserver LP 2000r comes standard with an IDE CD-ROM and a slim-line flexible disk drive,

Page 64

Chapter 3 Installing Mass Storage Devices 18 • SCSI Device Selection o Use only HP LVD low-profile (1 inch) SCSI 3.5-inch hard disk drives in the Ho

Page 65

Chapter 3 Installing Mass Storage Devices 19 CAUTION Thermal damage or excessive electromagnetic radiation may result if you operate the HP Netserve

Page 66

Chapter 3 Installing Mass Storage Devices 20 NOTE The boot order can be changed using the Netserver's (BIOS) Setup Utility and the SCSI Select

Page 67 - (4-Post)

Chapter 3 Installing Mass Storage Devices 21 CAUTION To prevent damage to the Hot Swap SCSI hard disk drives, do not use a HVD (high voltage differ

Page 68

Chapter 3 Installing Mass Storage Devices 22 TabTab Figure 3-2. Removing a Filler Panel 2. Remove the SCSI drive from its protective packaging a

Page 69

Chapter 3 Installing Mass Storage Devices 23 Figure 3-3. Inserting a SCSI Drive 4. Make sure the drive is pushed in completely. Close the eject

Page 70

iii Contents 1 Controls, Ports, and Indicators ... 1 Introduction ...

Page 71 - Marking Rack Columns

Chapter 3 Installing Mass Storage Devices 24 Figure 3-4. Closing Drive Ejector Arms 5. Verify that the drive is flush with the other drives. If

Page 72 - Screws (4)

Chapter 3 Installing Mass Storage Devices 25 Figure 3-5. Opening Drive Ejector Arms 2. Remove the drive: a. Using both hands, grasp the ejecto

Page 73

Chapter 3 Installing Mass Storage Devices 26 Figure 3-6. Removing a SCSI Drive Duplexing SCSI Hard Disk Drives This section provides instructio

Page 74

Chapter 3 Installing Mass Storage Devices 27 BACKPLANE ABACKPLANE BSCSI Channel ASCSI Channel BCable BCable CCable AExternal SCSI SCSI 3 SCSI 4 SCSI

Page 75

Chapter 3 Installing Mass Storage Devices 28 BACKPLANE ABACKPLANE BSCSI Channel ASCSI Channel BCable B(Cable A Removed)Cable CExternal SCSI SCSI 3 SC

Page 76

Chapter 3 Installing Mass Storage Devices 29 4. Fold the cables in the PCI card cage as shown in Figure 3-11. NOTE Ensure the cables do not imped

Page 77

Chapter 3 Installing Mass Storage Devices 30 Figure 3-10. Channel 0 and Channel 1 Connectors Figure 3-11. Folding Cables within the PCI Card Cag

Page 78

31 4 Installing Additional Memory Introduction The HP Netserver LP 2000r's main memory is implemented using four memory slots on the system boa

Page 79

Chapter 4 Installing Additional Memory 32 Memory Installation Guidelines • The HP Netserver LP 2000r only uses PC 133 (133 MHz) SDRAM DIMMs, which

Page 80

Chapter 4 Installing Additional Memory 33 Figure 4-1. Removing the Air Flow Guide 6. Locate the DIMM slots on the system board, and choose an

Page 81 - (2-Post)

Contents iv Memory Installation Guidelines ... 32 Installing Additional DIMMs ...

Page 82

Chapter 4 Installing Additional Memory 34 0123DIMMSlotsSystem Board (top view) Figure 4-2. DIMM Locations on System Board 7. Spread the two reta

Page 83

Chapter 4 Installing Additional Memory 35 9. Align the notches on the DIMM with the keys on the slot. See Figure 4-3. DIMMSlotKeysRetaining Latch

Page 84

Chapter 4 Installing Additional Memory 36 0123DIMMSlotsSystem Board Figure 4-4. Inserting DIMMs Removing DIMMs You may need to remove a DIMM module

Page 85

Chapter 4 Installing Additional Memory 37 5. Remove the air flow guide. See Figure 4-1. Refer to "Removing the Rear Chassis Blower/Bracket an

Page 87

39 5 Installing Additional Boards Introduction The HP Netserver LP 2000r provides three 64-bit PCI slots connected to a riser board contained in the

Page 88

Chapter 5 Installing Additional Boards 40 Accessory Board Installation Guidelines The following sections provide guidelines for installing PCI access

Page 89

Chapter 5 Installing Additional Boards 41 Remote Control Card The HP Netserver LP 2000r supports the HP Remote Control card, which uses the HP TopToo

Page 90

Chapter 5 Installing Additional Boards 42 IntegratedRA BoardICConnector2 Figure 5-2. Integrated RA Board Location Installing an Accessory Board Use

Page 91

Chapter 5 Installing Additional Boards 43 2. Press the power switch on the HP Netserver control panel to turn off power when prompted by the operati

Page 92

Contents v Attaching the Cable Management Arm ... 72 8 Rack Mounting the HP Netserver (2-Post

Page 93 - Mouse, and Power Supplies

Chapter 5 Installing Additional Boards 44 Lift Cage by Fan and Back Edge Figure 5-3. Removing the PCI Card Cage 8. Install the PCI card: a. Use a

Page 94

Chapter 5 Installing Additional Boards 45 Slot 3Slot 2Slot 1 Figure 5-4. Removing the Slot Cover

Page 95

Chapter 5 Installing Additional Boards 46 Figure 5-5. Inserting a PCI Card 9. When you have completed the PCI card installation, replace the PCI

Page 96 - Release Lever

Chapter 5 Installing Additional Boards 47 Guide Pin Figure 5-6. Replacing the PCI Card Cage 10. Replace the top cover on the HP Netserver and push

Page 98

49 6 Installing an Additional Processor Introduction The HP Netserver LP 2000r ships with at least one processor installed. Both primary and seconda

Page 99

Chapter 6 Installing an Additional Processor 50 Primary Processor (CPU1)SecondaryProcessor (CPU 2) Figure 6-1. System Board (top view) Installing

Page 100

Chapter 6 Installing an Additional Processor 51 CAUTION Take the following precautions when installing processors: • Leave the processor in the a

Page 101 - HP Management Solutions

Chapter 6 Installing an Additional Processor 52 6. Ensure the processor speed of the second processor (CPU 2) is the same as the primary processor.

Page 102 - Setup (BIOS) Utility

Chapter 6 Installing an Additional Processor 53 ZIF LeverTerminatorProcessorSocket Figure 6-2. Removing the Terminator NOTE Keep the terminator f

Page 103 - Menu Bar

Contents vi Introduction ... 105 Tools Required ...

Page 104 - Using the Setup Screens

Chapter 6 Installing an Additional Processor 54 CAUTION Ensure that you the align pin-1 of the processor with pin-1 of the processor socket or pin d

Page 105

Chapter 6 Installing an Additional Processor 55 Installing the Heatsink After installing a new processor, you need to install a heatsink on top of th

Page 106 - ➢Hardware Security

Chapter 6 Installing an Additional Processor 56 Hook Latch(hidden)Step ATabThumb LatchTabProcessorSocket Figure 6-4. Placing the Heatsink on the Proc

Page 107 - SCSI Configuration Utility

Chapter 6 Installing an Additional Processor 57 HoldDownToolLatchHook Latch Figure 6-5. Setting the Latches Firmware and Software Changes This sec

Page 108

Chapter 6 Installing an Additional Processor 58 Removing a Processor and Heatsink Use this procedure to remove a processor and its heatsink (the heat

Page 109 - Overview

Chapter 6 Installing an Additional Processor 59 3. Tilt the heatsink back towards the hook latch and release the hook latch. Then, lift the heatsink

Page 111 - 12 Troubleshooting

61 7 Rack Mounting the HP Netserver (4-Post) Introduction This chapter provides instructions for mounting the HP Netserver in 4-post HP System/E or

Page 112 - Common Installation Problems

Chapter 7 Rack Mounting the HP Netserver (4-Post) 62 Characteristics of System E andSystem U racks:a.b.c.d.e.5-Cornered ColumnsFull Panel Vent“HP Ra

Page 113 - Netserver Will Not Power On

Chapter 7 Rack Mounting the HP Netserver (4-Post) 63 HP Netserver Rack Mount Parts List Ensure the rack-mounting kit provided with the HP Netserver

Page 114 - Chapter 12 Troubleshooting

1 1 Controls, Ports, and Indicators Introduction Before operating the HP Netserver LP 2000r, familiarize yourself with the Netserver's controls

Page 115

Chapter 7 Rack Mounting the HP Netserver (4-Post) 64 Safety Precautions Always keep the following safety and environmental issues in mind, especiall

Page 116 - Resetting a Lost Password

Chapter 7 Rack Mounting the HP Netserver (4-Post) 65 Marking Rack Columns To make it easier to install the slides in the rack, you may want to mark

Page 117 - Hardware Problems

Chapter 7 Rack Mounting the HP Netserver (4-Post) 66 Installing Slides in the Rack 1. Ensure the rack is stabilized. For HP system /E or /U racks,

Page 118 - SCSI Device Does Not Work

Chapter 7 Rack Mounting the HP Netserver (4-Post) 67 Removing Slides from the Rack Follow these steps if you need to release the outer slide assembl

Page 119 - Replacing a Battery

Chapter 7 Rack Mounting the HP Netserver (4-Post) 68 Mounting the HP Netserver on the Slides Follow these steps to mount the HP Netserver on the sli

Page 120

Chapter 7 Rack Mounting the HP Netserver (4-Post) 69 Figure 7-5. Mounting the HP Netserver on the Slides

Page 121 - Introduction

Chapter 7 Rack Mounting the HP Netserver (4-Post) 70 Figure 7-6. Pressing the Stop Release Attaching the Front Bezel 1. Hook the bottom edge

Page 122

Chapter 7 Rack Mounting the HP Netserver (4-Post) 71 PinABPin Figure 7-7. Attaching the Bezel Cabling Rack Components After installing the HP Net

Page 123 - Rack Configuration Tools

Chapter 7 Rack Mounting the HP Netserver (4-Post) 72 Attaching the Cable Management Arm The Cable Management Arm (CMA) allows the cables and power c

Page 124 - Safety Precautions

Chapter 7 Rack Mounting the HP Netserver (4-Post) 73 3. Attach the Cable Management Arm to the HP Netserver: a. Insert the thumbscrew on the inne

Page 125 - Marking the Columns

Chapter 1 Controls, Ports and Indicators 2 CD-ROM Eject ButtonFDD Eject ButtonCD-ROM CD-ROM Activity LEDFDD Activity LEDFlexible Disk Drive(FDD)SCSI

Page 127

75 8 Rack Mounting the HP Netserver (2-Post) Introduction This chapter provides instructions for mounting the HP Netserver in a two-post non-HP rack

Page 128 - See Figure 13-5

Chapter 8 Rack Mounting the HP Netserver (2-Post) 76 Characteristics of2-Post Rack:A.B.C.U-shaped column for easyaccessTop is secured to ceiling to h

Page 129

Chapter 8 Rack Mounting the HP Netserver (2-Post) 77 The HP Netserver LP 2000r rack mount kit requires two EIA units of space in the rack. Before mou

Page 130

Chapter 8 Rack Mounting the HP Netserver (2-Post) 78 The white papers, particularly the HP Netserver High Density Rack Solutions Overview (LP 1000r a

Page 131 - Attaching the Front Bezel

Chapter 8 Rack Mounting the HP Netserver (2-Post) 79 Marking the Columns To make it easier to mount the HP Netserver in the rack, you may want to mar

Page 132 - Cabling Rack Components

Chapter 8 Rack Mounting the HP Netserver (2-Post) 80 Preparing the HP Netserver Before the HP Netserver can be mounted in the rack, you need to remov

Page 133

Chapter 8 Rack Mounting the HP Netserver (2-Post) 81 5. Attach the appropriate mounting brackets to the chassis, using the four screws provided for

Page 134

Chapter 8 Rack Mounting the HP Netserver (2-Post) 82 Figure 8-5. Attaching Center-Mount Brackets Mounting the HP Netserver in the Rack Follow thes

Page 135 - A Specifications

Chapter 8 Rack Mounting the HP Netserver (2-Post) 83 3. Insert a screw through the bottom hole on each bracket and tighten the screws sufficiently t

Page 136 - Appendix A Specifications

Chapter 1 Controls, Ports and Indicators 3 Table 1-2. Component Indicators LED ICON Description Temperature/Fan LED Error! Not a valid link. This

Page 137

Chapter 8 Rack Mounting the HP Netserver (2-Post) 84 Figure 8-7. Center Mounting the HP Netserver

Page 138 - System Board Layout

Chapter 8 Rack Mounting the HP Netserver (2-Post) 85 Attaching the Front Bezel The bezel attaches to the brackets on the front of the HP Netserver. 1

Page 140

87 9 Connecting the Monitor, Keyboard, Mouse, and Power Supplies Introduction Use the procedures in this chapter to connect the peripheral devices t

Page 141

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 88 Installing a Power Supply Module The HP Netserver LP 2000r comes with one power supply

Page 142

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 89 Figure 9-3. Removing the Power Supply Filler Panel 2. Before installing the new p

Page 143

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 90 Release Lever Figure 9-4. Moving Release Lever Down 3. Slide the module into the

Page 144

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 91 Removing a Power Supply Module If only one power supply module is used, it must be inst

Page 145

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 92 2. If you are not replacing the power supply module, insert the power supply filler p

Page 146

93 10 Configuring the HP Netserver Introduction This chapter describes how to configure the HP Netserver LP 2000r with the help of the HP Netserver