HP VMA-series Memory Arrays Guide de l'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 83
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 13
Single HP VMA SAN Gateway with 1–2
HP VMA-series Memory Arrays, Non Redundant
Figure 1.1 shows a configuration of a single VMA-series SAN Gateway is directly connected to a
group of up to two HP VMA-series Memory Arrays using PCIe cables. The HP VMA SAN
Gateway must be connected to Port 1 on each Memory Array in x8 mode.
Note: In the vSHARE software, Port A refers to the port that is labeled Port 1 on HP VMA-series
Memory Arrays. Port B refers to the port that is labeled Port 2.
Redundant Pair of VMA-series SAN Gateways with 1–2
HP VMA-series Memory Arrays, Highly Available
Figure 1.2 shows the most common configuration, a High Availability (HA) pair of VMA-series
SAN Gateways that provide redundant access to a group of up to two HP VMA-series Memory
Arrays.
In the example, SAN Gateway 1 is connected to Port A on each Memory Array, and SAN Gateway
2 is connected to Port B on each Memory Array. It is important that the Memory Gateways are
cabled to the Memory Arrays using identical slots for HA pairs. That is, if PCIe Slot 1 on SAN
Figure 1.1 Single HP VMA SAN Gateway with 2 HP VMA-series Memory Arrays, Non-Redundant
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 82 83

Commentaires sur ces manuels

Pas de commentaire