HP VMA-series Memory Arrays Guide de l'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 83
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 61
To ensure a proper MPIO operation, complete the following steps:
1. Install SP1 on Windows Server 2008 R2.
2. Install HotFix KB2522766 (from the Microsoft Support site).
3. Install HotFix KB2460971 (from the Microsoft Support site).
4. Install Hotfix KB2468345 (see the Microsoft Support site)
5. Install Hotfix KB2531907 (see the Microsoft Support site)
6. Install Hotfix KB2591462 (see the Microsoft Support site).
To change the load balance policy setting, complete the following steps:
1. Open the Registry Editor and navigate to:
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\v1010dsm\Parameters\DsmLoad
BalanceSettings\<EnumeratedViolin LUN>
2. Modify DWORD: DsmLoadBalancePolicy and change the value to 2 for all discovered LUNs.
3. Restart the client machine.
Disabling HA Mode for a LUN or Container
By default, LUNs are online via all available ports. LUNs are considered to be in HA mode when
they are online via both ports in the Array. If necessary, such as for debugging purposes, you can
explicitly take a LUN or a container out of HA mode, so that it is accessible via only one port.
For example, the following command removes the FINANCE LUN from HA mode by setting it
offline for Port B, and making it accessible only from Port A:
When the LUN has been taken out of HA mode, the
show luns command displays the status of
the LUN as
Single and indicates the port from which it is online. For example:
The following command sets a container offline from Port B, making it accessible only from Port A:
(config) # no lun set container Strad201 name FINANCE port B online
# show luns
Container: Strad201
LUN Size RW Bksz Status Ports
-------------------------------------------------------------------
FINANCE 10240M rw 512 Single A
(config) # no container set name Strad201 port B online