52 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A
To view existing containers, complete the following steps:
1. Log in as an administrator to the VMA Gateway attached to Port 1 of the HP VMA-series
Array.
2. Use the configure terminal command to enter Configure mode.
3. Enter the media block id all enable command to enable all block containers.
The
block parameter ensures that you enable vSHARE devices. The all parameter ensures
that every block container is enabled.
4. To view all the containers were created, enter the show containers command. Information
about the containers displays.
Configuring Target Ports
The second step in configuring a HP VMA SAN Gateway is to configure the target ports. The target
ports control access to a particular LUN, which may be useful for both security and bandwidth
management.
This section covers the following topics:
Supported Target Ports on page 49
Configuring Fibre Channel Target Ports on page 50
Supported Target Ports
In a vSHARE system, the HP VMA-series Arrays are the targets and the host system (for example,
one or more database servers or application servers) are the
initiators. The storage systems have
storage target devices (LUNs) that the hosts access through the HP VMA SAN Gateway.
The VMA SAN Gateway supports Fibre Channel target ports.
# configure terminal
(config) #
(config) # media <tab>
(config) # media block id all enable
> enable
# show containers
Container LUNs Total Free Ports HostnameA HostnameB
Status
----------------------------------------------------------------------
C-2 150 199G 50176M A,B <hostname> <hostname> cluster