HP VMA-series Memory Arrays Guide de l'utilisateur Page 57

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 83
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 56
AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 57
1. From the CLI, enter into Enable mode using the enable command and then Configure mode using the
configure terminal command.
2. All LUNs are created and managed within a container. To view the available containers, use
the show containers command.
Check the size of the containers. LUNs are implemented in 1 GB increments; the size of the
container may restrict the number of LUNs that may be created.
3. Enter the lun create command to create LUNs within a container.
The command creates 20 LUNs of equal size in the container. Use the
nozero option to ensure that
the data is not zeroed-out, which could take considerable time depending on the size of the
container.
Typically, fewer than 40 LUNs would be created within a container; however, the creation of up to
1024 LUNs is supported per container.
lun create Command
The
lun create command enables you to create a LUN within a specified storage container
connected to the VMA SAN Gateway.
Syntax
[no] lun create container <container_name> name <LUN_name> size [<size GB>
| equal] [quantity <number>] [nozero] [readonly] [startnum <unsigned
integer>] [blksize 512 | 4096] [offline]
Syntax Description
The following table shows syntax for LUN commands.
> enable
# configure terminal
(config) #
> enable
# configure terminal
(config) # show containers
(config) # lun create container <container_name> name <LUN_name> size
equal quantity 20 nozero
name
Defines the name of LUN to be created; used as a prefix if the
quantity of LUNs created is greater than one.
Vue de la page 56