Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 576
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
Creating Storagesets 329
Assigning Unit Numbers in Multiple Bus Failover Mode
In multiple bus failover mode, the range of assignable units, which are
accessible from any port on the subsystem, is 0-199. Hosts obtain units
by reserving the unit for sole access. This is done on a first-available
basis. Figure 311 illustrates the controller port ID and unit numbers in
multiple bus failover mode.
Figure 311 Controller Port ID Numbers and Unit Numbers in
Mulitple Bus Failover Mode
Assigning Unit Offsets
Unit offsets are used to define the first unit number that a host is able to
access on the controller. When assigning unit offsets, keep in mind that
the unit offset is settable on a per-host basis. Thus, one host can have a
unit offset of 0 and see units 0-99 as LUNs 0-99, and another host can
have a unit offset of 10 and see units 10-99 as LUNs 0-89 (controller
unit number 10 is seen at the host as LUN 0). This is useful for hosts
that have a limited LUN addressing range.
Figure 312 depicts the use of unit offsets on a per-host basis. Note that
controller units 0-99 are presented only on Port 1, and units 100-199
are presented only on Port 2. This implies that Port 1 hosts can have a
unit offset range of 0-99, and Port 2 hosts can have a unit offset range
of 100-199.
Controller A
Port 1 (Primary)
Units 0-199
Port 2 (Primary)
Units 0-199
Controller B
Port 1 (Primary)
Units 0-199
Port 2 (Primary)
Units 0-199
CXO6454A
Vue de la page 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 575 576

Commentaires sur ces manuels

Pas de commentaire