Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 186

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 576
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 185
432 HSG80 Users Guide
Checking Fibre Channel Link Errors
You can also use the display host VTDPY command to check for any
channel link errors (see Figure 45).
Note The following section outlines the VTDPY display for this
controller only. To see other connections, you must run VTDPY again
on the other controller.
HT% Cache-hit percentage for data transferred between the
host and the unit.
PH% Partial cache-hit percentage for data transferred between
the host and the unit.
MS% Cache-miss percentage for data transferred between the
host and the unit.
Purge Number of blocks purged from the cache during the last
update interval.
BlChd Number of blocks added to the cache during the last
update interval.
BlHit Number of blocks hit during the last update interval.
Table 48 Unit Status Columns (Continued)
Column Contents
Vue de la page 185
1 2 ... 181 182 183 184 185 186 187 188 189 190 191 ... 575 576

Commentaires sur ces manuels

Pas de commentaire