D70 HSG80 Users Guide
20100101 A config_node of type VA_MA_DEVICE had an unrecognized SCSI device type.
Last Failure Parameter[0] contains the SCSI device type number that was
unrecognized.
20110100 An attempt to allocate memory so the CLI prompt messages could be deleted failed.
20120101 While traversing the structure of a unit, a config_info node was discovered with an
unrecognized structure type.
Last Failure Parameter[0] contains the structure type number that was
unrecognized.
20130101 While traversing the structure of a unit, the device was of an unrecognized type.
Last Failure Parameter[0] contains the SCSI device type that was unrecognized.
20160000 In order to go into mirrored cache mode, the controllers must be restarted.
20160100 Unable to allocate resources needed for the CLI local program.
20170000 In order to go into unmirrored cache mode, the controllers must be restarted.
20190010 A cache state of a unit remains WRITE_CACHE_UNWRITTEN_DATA. The unit is
not ONLINE, thus this state would only be valid for a very short period of time.
201A0100 An attempt to allocate memory so a CLI prompt message could be reformatted failed.
201B0100 Insufficient resources to get memory to lock CLI.
201C0100 Insufficient resources to get memory to unlock CLI.
201D0100 With set failover copy=other, the controller which is having the configuration copied
to will automatically be restarted via this bugcheck.
201E0101 CLI$ALLOCATE_STRUCT() was called by a process which it does not support
Last Failure Parameter [0] contains pscb address.
201F0101 CLI$DEALLOCATE_ALL_STRUCT() was called by a process which it does not
support.
Last Failure Parameter [0] contains pscb address.
20200100 CLI$ALLOCATE_STRUCT() could not obtain memory for a new
nvfoc_rw_remote_nvmem structure.
20220020 This controller requested this subsystem to poweroff.
20230000 A restart of both controllers is required when exiting multibus failover.
Table D3 Last Failure Codes (Continued)
Code Description