Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 473

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 576
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 472
Event Reporting: Templates and Codes D39
010E0110
All structures contained in the System Information Page (SIP) and the Last Failure
entries have been reset to their default settings. This is a normal occurrence for the first
boot following manufacture of the controller module and during the transition from one
software version to another if and only if the format of the SIP is different between the
two versions. If this event is reported at any other time, follow the recommended repair
action associated with this Last Failure code.
010F0110 All structures contained in the System Information Page and the Last Failure entries
have been reset to their default settings as the result of certain controller
manufacturing configuration activities. If this event is reported at any other time,
follow the recommended repair action associated with this Last Failure code.
01100100 Non-maskable interrupt entered but no Non-maskable interrupt pending. This is
typically caused by an indirect call to address 0.
01110106 A bugcheck occurred during EXEC$BUGCHECK processing.
Last Failure Parameter [0] contains the executive flags value.
Last Failure Parameter [1] contains the RIP from the bugcheck call stack.
Last Failure Parameter [2] contains the first SIP last failure parameter value.
Last Failure Parameter [3] contains the second SIP last failure parameter value.
Last Failure Parameter [4] contains the SIP last failure code value.
Last Failure Parameter [5] contains the EXEC$BUGCHECK call last failure code
value.
01150106 A bugcheck occurred before subsystem initialization completed.
Last Failure Parameter [0] contains the executive flags value.
Last Failure Parameter [1] contains the RIP from the bugcheck call stack.
Last Failure Parameter [2] contains the first SIP last failure parameter value.
Last Failure Parameter [3] contains the second SIP last failure parameter value.
Last Failure Parameter [4] contains the SIP last failure code value.
Last Failure Parameter [5] contains the EXEC$BUGCHECK call last failure code
value.
Table D3 Last Failure Codes (Continued)
Code Description